½ÅÁ¦Ç°
Áß°íÁ¦Ç°
ƯÆǼҰ³
°èÃø±â ÀÔ°í List
´Ù¿î·Îµå
±ÝÀÏƯ°¡ÆǸÅ
ÀÔ°í¿¹Á¤ LIST
http://bank.keb.co.kr/
:::ÇöÀçÀ§Ä¡ HOME ¢º Áß°íÁ¦Ç° ¢º Calibrator/SourceMeter ¢º PROCESS CALIBRATOR Fluke 744
    
 
 
PROCESS CALIBRATOR Fluke 744
ÆǸŰ¡°Ý :  
ÁÖ¹®¼ö·® :
ºê·£µå : 01
ÇÕ°è±Ý¾× :  
  ¢¹ °£´ÜÇÑ ¼³¸í
  DOCUMENTING PROCESS CALIBRATOR
Fluke 744
- ´Ù±â´É ÇÁ·Î¼¼½º Ķ¸®ºê·¹ÀÌÅÍ´Â ¿Âµµ(TC/RTD), ¾Ð·Â, mA, , ÀúÇ×, ÁÖÆļö, Àü¾Ð µî¿¡ ´ëÇÏ¿© ÃøÁ¤ ¹× ¼Ò½Ì(Sourcing)À» ÇÒ ¼ö ÀÖÀ¸¸ç ÀÌ·¯ÇÑ ÃøÁ¤ ¹× ¼Ò½Ì¿¡ ´ëÇÑ ´Ù¾çÇÑ ¼³Á¤ÀÌ °¡´ÉÇÕ´Ï´Ù.

»óÅÂ : Used(Very Good)
°¡°Ý : Call

 
   
 
DOCUMENTING PROCESS CALIBRATOR

Fluke 744/743B/741B
 
  • FLUKE-744 ´Ù±â´É ÇÁ·Î¼¼½º Ķ¸®ºê·¹ÀÌÅÍ´Â ÇöÀå±³Á¤¿¡¼­ ÇÊ¿äÇÑ ¸ðµç ¹®Á¦µé¿¡ ´ëÇÏ¿© ½±°í Æí¸®ÇÏ°Ô ±× ÇØ°áÃ¥À» Á¦½ÃÇÒ °Í ÀÔ´Ï´Ù. ¿Âµµ(TC/RTD), ¾Ð·Â, mA, , ÀúÇ×, ÁÖÆļö, Àü¾Ð µî¿¡ ´ëÇÏ¿© ÃøÁ¤ ¹× ¼Ò½Ì(Sourcing)À» ÇÒ ¼ö ÀÖÀ¸¸ç ÀÌ·¯ÇÑ ÃøÁ¤ ¹× ¼Ò½Ì¿¡ ´ëÇÑ ´Ù¾çÇÑ ¼³Á¤ÀÌ °¡´ÉÇÕ´Ï´Ù.
        Specifications:
  • Measurement Accuracy
    Voltage DC110.000 mV0.025%+0.015% *
    1.10000 V0.025%+0.005% *
    11.0000 V0.025%+0.005% *
    110.000 V0.05%+0.005% *
    300.00 V0.05%+0.005% *
    Voltage AC20 to 40 Hz2% + 10
    40 to 500 Hz0.5% + 5
    500 to 1 kHz2% + 10
    1 kHz to 5 kHz10% + 20
    Ranges:1.1000, 11.000, 110.00, 300V
    Current DC30.000 mA0.01% + 0.015% *
    110.00 mA0.01% + 0.015% *
    Resistance11.000 ¥Ø0.05% + 50 m¥Ø
    110.00 ¥Ø0.05% + 50 m¥Ø
    1.1000 k¥Ø0.05% + 500 m¥Ø
    11.000 k¥Ø0.1% + 10 ¥Ø
    Frequency1.00 to 109.99 Hz0.05 Hz
    110.0 to 1099.9 Hz0.5 Hz
    1.100 to 10.999 kHz5 Hz
    11.00 to 50.00 kHz50 Hz
    PressureAccuracy from 0.025% of range using any of 29 pressure modules.
    Modules available for differential, gauge, vacuum, absolute, dual and high pressure.
    (for detailed specifications refer to pressure modules in options and accessories)
    Note* (% of reading + % of full scale)
    Source Accuracy
    Voltage DC110.000 mV0.01%+0.005% *
    1.10000 V0.01%+0.005% *
    15.0000 V0.01%+0.005% *
    Current DC22.000 mA (Source)0.01%+ 0.015% *
    22.000 mA (Simulate)0.02% + 0.03% *
    Resistance11.000 ¥Ø0.01% + 20 m¥Ø
    110.00 ¥Ø0.01% + 40 m¥Ø
    1.1000 k¥Ø0.02% + 500 m¥Ø
    11.000 k¥Ø0.03% + 5¥Ø
    Frequency0.00 to 10.99 Hz0.01 Hz
    11.00 to 109.99 Hz0.1 Hz
    110.0 to 1099.9 Hz0.1 Hz
    1100 to 21999 Hz2 Hz
    22.000 to 50.000 kHz5 Hz
    Note* (% of reading + % of full scale)
    RTDs and Thermocouples
    Measure Accuracy:10 ¥Ø Cu (427):2 ¡ÆC
    100 ¥Ø Pt (3916):0.3 ¡ÆC
    100 ¥Ø Pt (3926):0.3 ¡ÆC
    100 ¥Ø Pt (385):0.3 ¡ÆC
    200 ¥Ø Pt (385):0.3 ¡ÆC
    500 ¥Ø Pt (385):0.3 ¡ÆC
    1000 ¥Ø Pt (385):0.3 ¡ÆC
    120 ¥Ø Ni (672):0.3 ¡ÆC
    note:For 2-and 3-wire measurement, add 0.4¡ÆC
    E:0.3 ¡ÆC
    N:0.5 ¡ÆC
    J:0.3 ¡ÆC
    L:0.3 ¡ÆC
    K:0.3 ¡ÆC
    T:0.3 ¡ÆC
    U:0.3 ¡ÆC
    B:0.9 ¡ÆC
    R:1.0 ¡ÆC
    S:0.9 ¡ÆC
    C:0.6 ¡ÆC
    BP:1.2 ¨¬C
    XK:0.4 ¨¬C
    note:Accuracy with external cold junction, for internal junction add 0.2 ¡ÆC
    Source Accuracy:10 ¥Ø Cu (427):1 ¡ÆC
    100 ¥Ø Pt (3916):0.1 ¡ÆC
    100 ¥Ø Pt (3926):0.1 ¡ÆC
    100 ¥Ø Pt (385):0.1 ¡ÆC
    200 ¥Ø Pt (385):0.1 ¡ÆC
    500 ¥Ø Pt (385):0.1 ¡ÆC
    1000 ¥Ø Pt (385):0.1 ¡ÆC
    120 ¥Ø Ni (672):0.1 ¡ÆC
    note:For 2-and 3-wire simulation, add 0.4 ¡ÆC
    E:0.2 ¡ÆC
    N:0.3 ¡ÆC
    J:0.2 ¡ÆC
    L:0.2 ¡ÆC
    K:0.3 ¡ÆC
    T:0.3 ¡ÆC
    U:0.3 ¡ÆC
    B:0.8 ¡ÆC
    R:0.9 ¡ÆC
    S:0.9 ¡ÆC
    C:0.6 ¡ÆC
    BP:0.5 ¨¬C
    XK:0.4 ¨¬C
    note:Accuracy with external cold junction, for internal junction add 0.2 ¡ÆC
    Technical Data
    Data Log FunctionsMeasure functions:Voltage, current, resistance, frequency, temperature, pressure
    Reading rate:1, 2, 5, 10, 20, 30, or 60 readings/minute
    Maximum record length:8000 readings (7980 for 30 or 60 readings/minute)
    Ramp FunctionsSource functions:Voltage, current, resistance, frequency, temperature
    Rate:4 steps/second
    Trip detect:Continuity or voltage (continuity detection not available when sourcing current)
    Loop Power FunctionVoltage:Selectable, 24 V or 28 V
    Accuracy:5%
    Maximum current:22 mA, short circuit protected
    Maximum input voltage:30 V DC
    Step FunctionsSource FunctionsVoltage, current, resistance, frequency, temperature
    Manual StepSelectable step, change with arrow buttons
    AutostepFully programmable for function, start delay, stepvalue, time per step, repeat
    Environmental Specifications
    Operating Temperature-10 ¡ÆC to +50 ¡ÆC
    -20 ¡ÆC to +50 ¡ÆC *
    Storage Temperature-20 ¡ÆC to +60 ¡ÆC
    Dust/water resistanceMeets IP52, IEC 529
    Operating Altitude2800 m
    Note* Except frequency and AC
    Safety Specifications
    Agency ApprovalsCAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111, and EN610-1:1993
    Mechanical & General Specifications
    Size130 x 236 x 61 mm (5.1¡° x 9.3¡± x 2.4¡±)
    Weight1.4 kg (3 lbs., 1oz.)
    BatteriesNiMH: 7.2V, 3.5 Ah
    Battery Life>10 hours typical
    Battery ReplacementVia snap-shut door without opening calibrator; no tools required
    Side port connectionsPressure module connector
    RS-232 connector for PC interface cable and for HART communication cable
    Connection for optional battery eliminator
    Data storage capacity1 week of calibration results
    90 day specificationsThe standard specification interval for the 744 is 1 and 2 years.
    Typical 90 day measurement and source accuracy can be estimated by
    dividing the one year "% of reading" or "%of output" specifications by 2.
    Floor specifications, expressed as "% of full scale" or
    "counts" or "ohms" remain constant.



    744.jpg








      

     
     
    101-09-66502±èÁø¼ö
    ÁÖ¼Ò : ¼­¿ïƯº°½Ã Á¾·Î±¸ Á¾·Î26±æ 28(¿øâºôµù 158È£)
    ÀüÈ­¹øÈ£ : 02-2268-7345  Æѽº : 02-2263-7345
    USA Office :  3268 W 6th St Los Angeles CA90020 UNITED STATES
    YoungSir Trade Telecom co.
    e-mail :
    ys7345@korea.com/ys7345@hotmail.co.kr