  Next Generation Power Analyzer

PM1000+

°¡°Ý : 180¸¸¿ø(Used,Good)

 
   
 
Next Generation Power Analyzer
 
PM1000+
 
Display
 
The next generation PM1000 offers a high resolution QVGA display with unparalleled clarity.
The display allows up to 14 measurements to be viewed.
 
 
Specification
 
VOLTAGE RANGES
Frequency Range
Peak Continuous
Peak < 1 second
Input Impedance
Display
Crest Factor
900, 215, 46, 10 Vpk
10Hz to 1MHz
1500 Vpk (over voltage)
5000 Vpk (over voltage)
1 M¥Ø
4.5 Digits
20 (Peak / RMS)
RMS 45-65Hz Accuracy 0.05% of rdg +0.05% of
range
RMS Accuracy 0/1% of rdg + 0.1% of range
+ 4mV + (0.02 * F)% of rdg
DC Accuracy 0.1% of rdg + 0.4% of range
+ 5mV
VOLTAGE +/- PEAK Accuracy 0.5% of rdg + 0.5% of range
+ (0.02 * F)% of rdg
CURRENT RANGES
Frequency range
Peak Continuous
Peak < 1 second
Input resistance
Crest Factor
100, 25, 6.25, 1.6, 0.4, 0.1 Apk
10Hz to 1MHz
20Arms
60Arms (over current)
12.5m¥Ø
20 (Peak/RMS)
RMS 45-65Hz Accuracy 0.1% of rdg +0.1% of range
RMS Accuracy 0.1% of rdg + 0.1% of range
+ 1mA + (0.02 * F)% of rdg
DC Accuracy 0.1% of rdg + 0.4% of range
+ 1mA
CURRENT +/- PEAK Accuracy 0.5% of rdg + 0.5% of range +
(0.02 * F)% of rdg
WATTS RANGES
Frequency range
1W to 90kW
10Hz to 1MHz
RMS 45-65Hz Accuracy [{(Verror/Vreading)
+(Aerror/Areading)}*Wreading
+ 0.1% of W reading
  Accuracy 0.2% rdg + 0.1% range + 4mW
+ ((0.05/PF) * F)% of rdg
VA RANGES
Frequency range
Accuracy
1VA to 90kVA
10Hz to 1MHz
0.2% rdg + 0.1 % of range
+4mVA + (0.05 * F)% of rdg
VAr RANGES
Frequency range
Accuracy
1VAr to 90kVAr
10Hz to 1MHz
0.2% rdg + 0.1% range + 4mVAr
+((0.05/1-PF) * F)% of rdg
POWER FACTOR Power Factor Range
Accuracy
-1.000 to +1.000
+/-0.002 +/- ((0.001/PF) * F)
FREQUENCY RANGE
Accuracy
DC and 10Hz to 1MHz
0.1%
VOLTAGE CREST FACTOR RANGE
Accuracy
1.00 to 20.0
%Vpk error + % Vrms error
CURRENT CREST FACTOR RANGE
Accuracy
1.00 to 20.0
%Apk error + % Arms error
PEAK INRUSH CURRENT RANGE
Accuracy
100Apk
2% of range +/- 20mA
HARMONIC ANAYLSIS Number of Voltage &
Current Harmonics
Maximum Harmonics
Frequency
Accuracy

Frequency Range
50

450kHz
0.2% of Reading + 0.1% of range
+0.04% per kHz of Harmonics
10Hz to 450kHz
THD
Total Harmonic Distortion
Range & Accuracy

Formula
Range 0-999%
Accuracy 0.4% + (0.1 * F)% of reading
Series or difference
STANDBY POWER Time Window
Resolution
1-300 sec
1 second
IMPEDANCE Range
Accuracy
0.005¥Ø to 1M¥Ø
0.2% of Reading +0.1% of range
+5m¥Ø + ((0.05/PF) * F)% of reading
RESISTANCE Range
Accuracy
0.005¥Ø to 1M¥Ø
0.2% of Reading + 0.1% of range
+5m¥Ø + ((0.05/1-PF) * F)% of reading
REACTANCE Range
Accuracy
0.005¥Ø to 1M¥Ø
0.2% of reading + 0.1% of range
+5m¥Ø + ((0.05/PF) * F)% of reading
EXTERNAL SHUNT
Scaling
Input Range +/- 1250 mVpk
0.0001 to 100000
MECHANICAL   1/2 rack size. Rack height 85mm
W = 224mm. Height including feet 103mm
D = 285mm. Weight 3.21Kg (7lbs.)
 