AC Power Analyzer
PM100(´Ü»ó)
Measurements
Watts, Volts, Amps, VA, VAr, PF, cos phi, Vrms, Vpeak, Vcf, Arms, A peak, Acf, Frequency
THD, voltage, current and power harmonics
Programmable for watt-hour, ampere-hour and other integrator measurements
Special modes for Inrush Current and low power (including Energy Star) measurements
Available with IEEE488 or RS232 communications interfaces installed
Features and Performance 0.1% basic accuracy DC to 250kHz bandwidth 1000Vpk / 20A RMS direct inputs Graphics display of waveforms and harmonic barcharts W, V, A, VA, Var, Power factor, Cosf, Vpk, Apk, crest factors and frequency Channel 1, 2, 3, SUM(S) and neutral quantities on the PM300 three-phase analyzer Harmonics V, A (incl. phase) and W to the 50th Total Harmonic Distortion Integrator for W-hr, VA-hr, A-hr, VA-hr, average and target PF Easy-to-use menu structure available in different languages Accepts and scales for external current and voltage transducers IEEE488, RS232, printer, chart recorder and alarm interface cards available VPAS Lite Windows software for control and data handling
Basic Measurements W, V, A, VA, Var, power factor, Vpk, Apk, crest factors and frequency Channel 1, 2, 3, Sum(S) and neutral quantities on 3-phase analyzers Harmonics V, A, (including phase) and W Total Harmonic Distortion Integrator for W-hr, VA-hr, A-hr, VA-hr, average and target PF
Special Features
Amps inrush Continuous fast sampling captures the peak inrush current Ballast mode for testing the output of electronic lighting ballast Reliable measurements of tube current and power
Optional Interface Cards IEEE488 for high speed control and data capture RS232 and parallel printer interface. The RS232 serial port allows complete command and results handling as IEEE488. The parallel printer port may be connected directly to a standard printer with a parallel interface for printing displayed or numeric results. Chart recorder and alarm interface. Twelve 0-5V DC outputs track any measurement parameter desired. Two free relay contacts can be programmed to toggle at any selected level for alarm or process control purposes. The twelve chart recorder outputs may also be configured as digital alarm
PM300 showing interface card location
Software
VPAS Lite Windows software for control and data handling features quick and easy set-up of parameters for analysis plus display of numeric data and harmonic bar charts. Data may be exported to standard PC text and spreadsheet applications for further presentation
Manual ÂüÁ¶
Data Sheet ÂüÁ¶
|
|