Three-Phase Power Analyzer
Voltech PM300(3»ó)
Measurements
Watts, Volts, Amps, VA, VAr, PF, cos phi, Vrms, Vpeak, Vcf, Arms, A peak, Acf, Frequency
THD, voltage, current and power harmonics
Programmable for watt-hour, ampere-hour and other integrator measurements
Special modes for Inrush Current and low power (including Energy Star) measurements
Available with IEEE488 or RS232 communications interfaces installed
Features and Performance
0.1% basic accuracy
DC to 250kHz bandwidth
1000Vpk / 20A RMS direct inputs
Graphics display of waveforms and harmonic barcharts
W, V, A, VA, Var, Power factor, Cosf, Vpk, Apk, crest factors and frequency
Channel 1, 2, 3, SUM(S) and neutral quantities on the PM300 three-phase analyzer
Harmonics V, A (incl. phase) and W to the 50th
Total Harmonic Distortion
Integrator for W-hr, VA-hr, A-hr, VA-hr, average and target PF
Easy-to-use menu structure available in different languages
Accepts and scales for external current and voltage transducers
IEEE488, RS232, printer, chart recorder and alarm interface cards available
VPAS Lite Windows software for control and data handling
Basic Measurements
W, V, A, VA, Var, power factor, Vpk, Apk, crest factors and frequency
Channel 1, 2, 3, Sum(S) and neutral quantities on 3-phase analyzers
Harmonics V, A, (including phase) and W
Total Harmonic Distortion
Integrator for W-hr, VA-hr, A-hr, VA-hr, average and target PF
Special Features
Amps inrush
Continuous fast sampling captures the peak inrush current
Ballast mode for testing the output of electronic lighting ballast
Reliable measurements of tube current and power
Optional Interface Cards
IEEE488 for high speed control and data capture
RS232 and parallel printer interface. The RS232 serial port allows complete command and results handling as IEEE488. The parallel printer port may be connected directly to a standard printer with a parallel interface for printing displayed or numeric results.
Chart recorder and alarm interface. Twelve 0-5V DC outputs track any measurement parameter desired. Two free relay contacts can be programmed to toggle at any selected level for alarm or process control purposes. The twelve chart recorder outputs may also be configured as digital alarm
PM300 showing interface card location
Software
VPAS Lite Windows software for control and data handling features quick and easy set-up of parameters for analysis plus display of numeric data and harmonic bar charts. Data may be exported to standard PC text and spreadsheet applications for further presentation