½ÅÁ¦Ç°
Áß°íÁ¦Ç°
ƯÆǼҰ³
°èÃø±â ÀÔ°í List
´Ù¿î·Îµå
±ÝÀÏƯ°¡ÆǸÅ
ÀÔ°í¿¹Á¤ LIST
:::ÇöÀçÀ§Ä¡ HOME
¢º
Áß°íÁ¦Ç°
¢º
LCR Meter/ Probe/GPIB Card
¢º LCR Meter Fluke PM6303A.6306
LCR Meter Fluke PM6303A.6306
ºê·£µå
:
03
¢¹ °£´ÜÇÑ ¼³¸í
Digital LCR Meter
PM6303A
Test frequencies from 1KHz
°¡°Ý :\450,000
PM6304
Test frequencies from 50 Hz to 100KHz
°¡°Ý :\1400000
- Test Probe Æ÷ÇÔ
PM6306
Test frequencies from 50 Hz to 1MHz
°¡°Ý :1,800,0000
- Test Probe Æ÷ÇÔ
Programmable RCL Meter
Fluke PM6306/PM6304
AC Test Mode
Test frequency
PM 6306
:
50, 60, 100, 120 Hz
200 Hz to 100 kHz (100 Hz steps)
100 kHz to 1 MHz (1 kHz steps)
PM 6304:
50, 60, 100, 120 Hz
200 Hz to 20 kHz (100 Hz steps)
100 kHz
Test frequency accuracy
PM 6306:
0.01%
PM 6304:
0.01%
Test signal levels
PM 6306:
50 mV to 2V (10 mV steps) via 100¥Ø
PM 6304:
50 mV via 100¥Ø
1V via 100¥Ø
2V via 400¥Ø
Basic measurement accuracy at normal measurement mode
PM 6306:
0.1% ¡¾ 1 digit (for
©ø
0.25V,
£
50 kHz)
0.1% * (f/50 kHz) ¡¾ 1 digit (for
©ø
0.25V, > 50 kHz)
0.1% * (0.25V/Vt) ¡¾ 1 digit (for < 0.25V,
£
50 kHz)
PM 6304:
0.05% ¡¾ 1 digit (for PM 6304C,
£
2 kHz)
0.1% ¡¾ 1 digit (for
£
20 kHz)
0.4% ¡¾ 1 digit (100 kHz)
0.5% ¡¾ 1 digit (for 50 mV
£
20 kHz)
2.0% ¡¾ 1 digit (for 50 mV, 100 kHz)
DC bias
Internal
PM 6306:
0 to 10V (0.1V steps)
PM 6304:
2V
External
PM 6306:
0 to 40V
PM 6304:
0 to 40V
DC test mode (Optional)
Test signal levels
PM 6306:
50 mV to 2V (10 mV steps) via 100¥Ø
PM 6304:
300 mV via 100¥Ø
1V via 100¥Ø
2V via 400¥Ø
Basic measurement accuracy
PM 6306:
0.1% ¡¾ 1 digit (for
©ø
0.25V
)
PM 6304:
0.1% ¡¾ 1 digit (for 1V)
Contact check (PM 6306 only)
Pass
3 3¥Ø
Fail
3¥Ø (with indication of failed connection lead)
Maximum measuring ranges
Impedance/Resistance AC Z or R
AC
0.0000¥Ø to 200 M¥Ø
Resistance DC R
DC
0.0000¥Ø to 50 M¥Ø
Capacitance C
0.00 pF to 31.8F
Inductance L
0.00
m
H to 637 kH
Quality factor Q
0.000 to 1000
Dissipation factor D
0.000 to 1000
Phase Angle
F
-179 to + 180 deg
Voltage monitor V
X
0.1 mV to 2.00V
Current monitor I
X
0.005 mA to 10.0 mA
Maximum resolution
Impedance/Resistance AC Z or R
AC
0.1 m¥Ø
Resistance DC R
DC
0.1 m¥Ø
Capacitance C
0.01 pF
Inductance L
0.01 mH
Quality factor Q
0.001
Dissipation factor D
0.001
Phase Angle
F
0.1 deg
Voltage monitor V
X
0.1 mV
Current monitor I
X
0.001 mA
Circuit diagram
Display
1 of 7 different equivalent circuit diagrams
Auto Mode
Read-out
Dominant and secondary parameter
Equivalent circuit diagram
Parallel for R+C, Serial for R+L
Manual mode
Read-out
Dominant and secondary parameter or Z,
F
, D, Q, VX, IX
Equivalent circuit diagram
Parallel or serial selectable
Average function
Function
Exponential averaging in continuous mode
Levels
PM 6306:
3 (and off)
PM 6304:
1 (and off)
Deviation mode (PM 6306 only)
Relative range in respect to reference value
-100% to +100%
Measuring modes (Normal)
Continuous
2 measurements/s
Single
Triggered via "TRIG" key
Triggered via handler interface
Triggered via IEEE-488 or RS-232
Test frequency
PM 6306:
50, 60, 100, 120 Hz
200 Hz to 100 kHz (100 Hz steps)
100 kHz to 1 MHz (1 kHz steps)
DC (optional)
PM 6304:
50, 60, 100, 120 Hz
200 Hz to 20 kHz (100 Hz steps)
100 kHz
DC (optional)
Read-out
Display or via IEEE-488 or RS-232 interface
Measuring Modes (Fast)
Max. speed
10 measurements/s
Test frequency
PM 6306:
200 Hz to 100 kHz (200 Hz steps)
100 kHz to 1 MHz (1 kHz steps)
DC (optional)
PM 6304:
200 Hz to 20 kHz (200 Hz steps) 100 kHz
DC (optional)
Single
Triggered via handler interface
Triggered via IEEE-488 or RS-232
Read-out
Via IEEE or RS-232 interface (display blanked)
Binning
Standard bins
9
Special bins
Bin "0" and bin "fail"
Bin programming via
IEEE-488 interface
RS-232 interface
Bin programmer (PM 6304 only)
Bin limit programming
Absolute or relative
Trim function
Open circuit
Open circuit compensation Z > 100 kW
Short circuit
Short circuit compensation Z < 10W
Protection against charged capacitors
C < 2 mF
PM 6306:
V
max
< 200V
PM 6304:
V
max
< 500V
2 mF o C o 2 mF
PM 6306:
V
max
<47 x (C/mF)
-0.234
(Vmax in V, C in mF)
PM 6304:
V
max
<117 x (C/mF)
-0.234
(Vmax in V, C in mF)
Stored settings (non-volatile memory)
Front panel settings
9 + 1 (trim figures included)
Bin settings
9 + 1
Print measurements results
Print measurements results
Via RS-232 interface for serial printers
Calibration interval
Calibration interval
1 year
Environmental Conditions
Operating Temperature
0¡Æ to 50¡Æ C
Storage Temperature
-40¡Æ C to 70¡Æ C
Power, battery life
100/120/220/240V + 10%
Line frequency
50/60 Hz
Power Consumption
PM 6306:
44 VA
PM 6304:
31 VA
Safety
According to CE-regulation 73/23 EN61010-1 CAT II, Pollution Degree 2
EMC
According to CE regulation 89/336: Emission according to EN 55011, Group 1 Class B, respectively CISPR 11. Immunity according to EN 50082-1, inclusive IEC 801-2, -3, -4
Warm up Time
PM 6306:
30 minutes
PM 6304:
5 minutes
Dimensions and weight
W x H x D
315 x 105 x 405 mm (12.4 in x 4.13 in x 15.9 in)
Weight
PM 6306:
5.3 kg (11.7 lb)
PM 6304:
4.7 kg (10.4 lb)
101-09-66502±èÁø¼ö
ÁÖ¼Ò : ¼¿ïƯº°½Ã Á¾·Î±¸ Á¾·Î26±æ 28(¿øâºôµù 158È£)
ÀüȹøÈ£ : 02-2268-7345 Æѽº : 02-2263-7345
USA Office : 3268 W 6th St Los Angeles CA90020 UNITED STATES
YoungSir Trade Telecom co.
e-mail :
ys7345@korea.com
/
ys7345@hotmail.co.kr
²ô±â