http://bank.keb.co.kr/
:::ÇöÀçÀ§Ä¡ HOME ¢º Áß°íÁ¦Ç° ¢º LCR Meter/ Probe/GPIB Card ¢º LCR Meter Fluke PM6303A.6306
    
 
 
LCR Meter Fluke PM6303A.6306
ºê·£µå : 03
  ¢¹ °£´ÜÇÑ ¼³¸í
  Digital LCR Meter
PM6303A
Test frequencies from 1KHz
°¡°Ý :\450,000
PM6304
Test frequencies from 50 Hz to 100KHz
°¡°Ý :\1400000
- Test Probe Æ÷ÇÔ
PM6306
Test frequencies from 50 Hz to 1MHz
°¡°Ý :1,800,0000
- Test Probe Æ÷ÇÔ
 
 
 
Programmable RCL Meter
 
Fluke PM6306/PM6304
 
AC Test Mode
Test frequency
PM 6306: 50, 60, 100, 120 Hz
  200 Hz to 100 kHz (100 Hz steps)
  100 kHz to 1 MHz (1 kHz steps)
PM 6304: 50, 60, 100, 120 Hz
  200 Hz to 20 kHz (100 Hz steps)
  100 kHz
Test frequency accuracy
PM 6306: 0.01%
PM 6304: 0.01%
Test signal levels
PM 6306: 50 mV to 2V (10 mV steps) via 100¥Ø
PM 6304: 50 mV via 100¥Ø
  1V via 100¥Ø
  2V via 400¥Ø
Basic measurement accuracy at normal measurement mode
PM 6306: 0.1% ¡¾ 1 digit (for ©ø 0.25V, £ 50 kHz)
  0.1% * (f/50 kHz) ¡¾ 1 digit (for ©ø 0.25V, > 50 kHz)
  0.1% * (0.25V/Vt) ¡¾ 1 digit (for < 0.25V, £ 50 kHz)
PM 6304: 0.05% ¡¾ 1 digit (for PM 6304C, £ 2 kHz)
  0.1% ¡¾ 1 digit (for £ 20 kHz)
  0.4% ¡¾ 1 digit (100 kHz)
  0.5% ¡¾ 1 digit (for 50 mV £ 20 kHz)
  2.0% ¡¾ 1 digit (for 50 mV, 100 kHz)
DC bias
Internal
PM 6306: 0 to 10V (0.1V steps)
PM 6304: 2V
External
PM 6306: 0 to 40V
PM 6304: 0 to 40V
DC test mode (Optional)
Test signal levels
PM 6306: 50 mV to 2V (10 mV steps) via 100¥Ø
PM 6304: 300 mV via 100¥Ø
  1V via 100¥Ø
  2V via 400¥Ø
Basic measurement accuracy
PM 6306: 0.1% ¡¾ 1 digit (for ©ø 0.25V)
PM 6304: 0.1% ¡¾ 1 digit (for 1V)
Contact check (PM 6306 only)
Pass
  3 3¥Ø
Fail
  3¥Ø (with indication of failed connection lead)
Maximum measuring ranges
Impedance/Resistance AC Z or RAC
  0.0000¥Ø to 200 M¥Ø
Resistance DC R DC
  0.0000¥Ø to 50 M¥Ø
Capacitance C
  0.00 pF to 31.8F
Inductance L
  0.00 mH to 637 kH
Quality factor Q
  0.000 to 1000
Dissipation factor D
  0.000 to 1000
Phase Angle F
  -179 to + 180 deg
Voltage monitor VX
  0.1 mV to 2.00V
Current monitor IX
  0.005 mA to 10.0 mA
Maximum resolution
Impedance/Resistance AC Z or RAC
  0.1 m¥Ø
Resistance DC R DC
  0.1 m¥Ø
Capacitance C
  0.01 pF
Inductance L
  0.01 mH
Quality factor Q
  0.001
Dissipation factor D
  0.001
Phase Angle F
  0.1 deg
Voltage monitor VX
  0.1 mV
Current monitor IX
  0.001 mA
Circuit diagram
Display
  1 of 7 different equivalent circuit diagrams
Auto Mode
Read-out
  Dominant and secondary parameter
Equivalent circuit diagram
  Parallel for R+C, Serial for R+L
Manual mode
Read-out
  Dominant and secondary parameter or Z, F, D, Q, VX, IX
Equivalent circuit diagram
  Parallel or serial selectable
Average function
Function
  Exponential averaging in continuous mode
Levels
PM 6306: 3 (and off)
PM 6304: 1 (and off)
Deviation mode (PM 6306 only)
Relative range in respect to reference value
  -100% to +100%
Measuring modes (Normal)
Continuous
  2 measurements/s
Single
  Triggered via "TRIG" key
  Triggered via handler interface
  Triggered via IEEE-488 or RS-232
Test frequency
PM 6306: 50, 60, 100, 120 Hz
  200 Hz to 100 kHz (100 Hz steps)
  100 kHz to 1 MHz (1 kHz steps)
  DC (optional)
PM 6304: 50, 60, 100, 120 Hz
  200 Hz to 20 kHz (100 Hz steps)
  100 kHz
  DC (optional)
Read-out
  Display or via IEEE-488 or RS-232 interface
Measuring Modes (Fast)
Max. speed
  10 measurements/s
Test frequency
PM 6306: 200 Hz to 100 kHz (200 Hz steps)
  100 kHz to 1 MHz (1 kHz steps)
  DC (optional)
PM 6304: 200 Hz to 20 kHz (200 Hz steps) 100 kHz
  DC (optional)
Single
  Triggered via handler interface
  Triggered via IEEE-488 or RS-232
Read-out
  Via IEEE or RS-232 interface (display blanked)
Binning
Standard bins
  9
Special bins
  Bin "0" and bin "fail"
Bin programming via
  IEEE-488 interface
  RS-232 interface
  Bin programmer (PM 6304 only)
Bin limit programming
  Absolute or relative
Trim function
Open circuit
  Open circuit compensation Z > 100 kW
Short circuit
  Short circuit compensation Z < 10W
Protection against charged capacitors
C < 2 mF
PM 6306: Vmax < 200V
PM 6304: Vmax < 500V
2 mF o C o 2 mF
PM 6306: Vmax <47 x (C/mF) -0.234
  (Vmax in V, C in mF)
PM 6304: Vmax <117 x (C/mF) -0.234
  (Vmax in V, C in mF)
Stored settings (non-volatile memory)
Front panel settings
  9 + 1 (trim figures included)
Bin settings
  9 + 1
Print measurements results
Print measurements results
  Via RS-232 interface for serial printers
 
 