ACTERNA DSAM-2600
- 4 to 1000 MHz tuning range; 8 MHz and 6 MHz models
- Quick QAM summary of 64 and 256 QAM carrier performance
- ÃæÀü±â Æ÷ÇÔÀÓ
ACTERNA DSAM-3600B \2,700,000
ACTERNA DSAM-2600B \2,500,000
ACTERNA DSAM-2500B \2,300,000
ACTERNA DSAM-1000B \1,500,000
# ±¸ÀԽà °¡°Ý ¹®ÀÇ¿ä¸Á
Digit
al activation meter
ACTERNA DSAM-3600/2600/2500/1000B
¤ýµðÁöÅÐ ½ÅÈ£ 󸮱â¼ú(DSP)À» äÅÃÇÏ¿© ´Ú½Ã½º(DOSCIC) ÄÉÀ̺í¸ðµ© ¼ºñ½º, µðÁöÅÐ ¿µ»ó ¼ºñ½º,
¾Æ³¯·Î±× ¿µ»ó ¼ºñ½º, ÀÎÅÍ³Ý ±â¹ÝÀÇ À½¼ºÅë½Å(VoIP) ¼ºñ½º Å×½ºÆ®¸¦ ÇÑ Àåºñ¿¡¼ ±¸Çö
¤ý¾Æ³¯·Î±× ½ÅÈ£ ÃøÁ¤ ³»Æ÷(·¹º§, 12ä³Î Æ¿Æ® ¹× ½ºÄµ, Àüä³Î ½ºÄµ, Àü´ë¿ª ½ºÆåÆ®·³, ÀÚµ¿ÃøÁ¤ µîµî)
¤ýµðÁöÅÐ ½ÅÈ£ ÃøÁ¤ ³»Æ÷(64/256QAM ºÐ¼®, MER/BER/EVM ÃøÁ¤, Constellation, Doscic, IPºÐ¼®,
¼ÓµµÅ×½ºÆ®, »óÇâÆÐŶ¼Õ½Ç ÃøÁ¤, S/R ÃøÁ¤, PING Å×½ºÆ®, ÀÎÅÍ³Ý Á¢¼Ó Å×½ºÆ® µîµî)
¤ýÁ¦Ç°ÀÇ °ß°íÇÔ°ú »ýÈ°¹æ¼ö 󸮴ɷ Çâ»ó
¤ýµöÀÎÅ͸®ºù ÃøÁ¤
¤ýCW,16QAM ½ÅÈ£ ¹ß»ý±â ³»Àå
¤ý¾Æ³ª·Î±× C/NÃøÁ¤ °¡´É
Acterna DSAM-2600B Digital Service Activation Meter
Specifications:
Frequency:
Range: 4 to 1,000 MHz
Accuracy: ¡¾10 ppm at 77¡ÆF (25¡ÆC)
Tuning Resolution:
Analog: 10 KHz
Digital: 50 KHz
Channel Bandwidth: 6 MHz
Analog Level Measurements:
Signal Types: CW, video and audio (NTSC, PAL, and SECAM)
Range: -40 to +60 dBmV
Resolution: 0.1 dB
Resolution Bandwidth: 330 KHz
Accuracy: ¡¾1.5 dB typical @ 25¡ÆC
Digital Level Measurements:
Modulation Types: QPR, QPSK, QAM (DVB/ACTS)
Range: -40 to +60 dBmV
Resolution: 0.1 dB
Resolution Bandwidth: 330 kHz
Accuracy: ¡¾2.0 dB typical @ 25¡ÆC
Upstream Spectrum:
Spans: 4 to 45 MHz
Sweep Rate: 1.8 seconds or faster
Display Scaling & Range: 5 and 10 dB/division; 6 vertical divisions
Sensitivity: -35 to 60 dBmV
DOCSIS/EuroDOCSIS compatibility: 5 to 42 MHz 42/88 MHz (min. downstream DOCSIS center freq. 100 MHz
Installed Measurement Options:
Level Measurement
Mini Scan
Full Scan
Tilt
FDR Locate
Hum
Upstream Spectrum
Ingress Resistance
And lots more.
That meter is the beast.
Manual :
http://www.jdsu.com/product-literature/DSAM_QS_Guide_RevB_English.pdf
101-09-66502±èÁø¼ö
ÁÖ¼Ò : ¼¿ïƯº°½Ã Á¾·Î±¸ Á¾·Î26±æ 28(¿øâºôµù 158È£)
ÀüȹøÈ£ : 02-2268-7345 Æѽº : 02-2263-7345
USA Office : 3268 W 6th St Los Angeles CA90020 UNITED STATES
YoungSir Trade Telecom co.
e-mail :
ys7345@korea.com
/
ys7345@hotmail.co.kr
²ô±â